Product SEN-10736 | about 8 months ago
Don’t expect to get a working out of the box AHRS with this board and the associated software (or the Mongoose software) without a correct calibration of the magnetometer … On mine, I had large hard-iron and non negligible soft-iron errors
I did. It’s very simple. The 6 pin row connector is directly compatible with an XBee.
Product SEN-10736 | about 10 months ago
I tried the following code http://www.drotek.fr/ftp/HMC5883.pde and data seem to be ok so the test firmware is probably outdated
I do have exactly the same problem with the same configuration. Are these boards tested with this test firmware after production ?
No public wish lists :(
Product SEN-10736 | about 8 months ago
Don’t expect to get a working out of the box AHRS with this board and the associated software (or the Mongoose software) without a correct calibration of the magnetometer … On mine, I had large hard-iron and non negligible soft-iron errors
Product SEN-10736 | about 8 months ago
I did. It’s very simple. The 6 pin row connector is directly compatible with an XBee.
Product SEN-10736 | about 10 months ago
I tried the following code
http://www.drotek.fr/ftp/HMC5883.pde
and data seem to be ok so the test firmware is probably outdated
Product SEN-10736 | about 10 months ago
I do have exactly the same problem with the same configuration. Are these boards tested with this test firmware after production ?