SparkFun Electronics Commentsurn:uuid:214d0e4e-f1b1-d287-ce26-ac5b4c9f82492024-03-29T16:13:10-06:00SparkFun ElectronicsSembazuru on SparkFun's EAGLE resourcesSembazuruurn:uuid:f8082d78-cf46-9b01-9c59-1cb917b529352016-04-11T22:50:00-06:00<p>Same here, sort of... I had made a change (40-pin DIP to 44pin PLCC) on a board that had 3 separate plane pairs (digital power & gnd, analog power & gnd, and patient isolation power & gnd). When we got the boards back and populated the first 10 with components. The test & calibrate department found that two of the 3 planes didn't have any thermal relieves to plated holes and vias... ooops... I think the patient isolation pair were one of the two unconnected, so they were really isolated. ;-)<p>I never did live that one down at that company. Luckily for me an engineer had signed off on the photo-plots so there were plenty to help share blame. Check-out procedures were enhanced after that...</p></p>
Mondkin on SparkFun's EAGLE resourcesMondkinurn:uuid:b4587421-6e29-8853-2a9c-2f2febc814ab2016-04-11T21:22:32-06:00<p>Losing the ground plane ... I'm guilty of that too.</p>
Chelsea the Destroyer on SparkFun's EAGLE resourcesChelsea the Destroyerurn:uuid:5b38e2a0-fae2-3e6e-03a7-e961a1002be52016-04-11T14:55:37-06:00<p>Yes! We added it to the supercategories on the upper left side of the homepage. Good call, thank you!</p>