tessar

Member Since: January 26, 2011

Country: United States

  • Product SEN-10061 | about 3 years ago

    Hello,
    I asked directly at LinkSprite company support. They told me I have to send the camera back to the factory to replace/fix the firmware. Looks like it is not possible to fix this problem by myself.
    So my conclusion:
    This is a nice camera wich much better communication and stability performance than the one from 4dSystems, but:
    DON’T MESS WITH THE PICTURE SIZE COMMAND
    Tessar

  • Product SEN-10061 | about 3 years ago

    Hello,
    I have a big problem:
    I send the wrong command to set the resolution. It should be “56 00 31 05 04 01 00 19 22” but I sended “33” at the end instead of “22”. After reboot my camera don’t finish init. It don’t respond to my commands to change the image size to the correct value, actually it don’t respond to any command.
    Is there a way to clear the EEPROM or reset to a default state?
    This is the 2nd camera where that happens (for the first one I didn’t recognize, it was the wrong code that killed it but when I think back, it didn’t work after changing the resolution)
    Please HELP!!!!