    I’m not sure if it was corrected in this kit but there is an error in the code for voltage mode in the KIT-10338 kit. The calculation gives you the voltage at the AD input and NOT the voltage at the probe. The calculation should multiply by 3.281*1.12/1.2=3.062, not by 3.281. That would fix the voltage error reported by bdodds on the old kit. Basically, the calculation does not factor in the voltage divider (which needs to be scaled by 10X due to the decimal point).

  • Product KIT-10338 | about 2 years ago

    There is an error in the code for voltage mode. The calculation gives you the voltage at the AD input and NOT the voltage at the probe. The calculation should multiply by 3.281*1.12/1.2=3.062. That would fix the error reported by bdodds. The claculation does not factor in the voltage divider (which needs to be scaled by 10X due to the decimal point.